Cold deck roof a cold deck roof is where the insulation is placed between the joists rafters or in between the ceiling joists in the case of a pitch roof.
Cold deck roof insulation.
It can also be used as a roofing cover board and in building envelope applications.
Ratio of r value between rigid insulation and batt insulation is climate dependent.
If spray foam is used a vent space may still be needed directly under the roof deck.
Warm roof insulation ensures the entire roof structure is insulated meaning a warm deck roof is more energy efficient than a cold roof.
Care should be taken with these assemblies particularly in cold climate zone locations i e.
Guidance advice on.
Where insulation depth is restricted by the flat roof construction it may be necessary to install the roof insulation between and below the joists to create a cold deck structure.
This method of insulation can also be used to upgrade the thermal performance of an existing roof without affecting the waterproofing system.
To create a cold roof we provide each rafter bay with a full width vent chute that leaves a 1 1 2 inch air channel under the roof deck.
Ventilation is required for these roofs.
It is a thermoset closed cell foam that is an optimal insulation solution for low slope roofs.
A cold flat roof insulation requires more work taking off old boards and replacing them and the roof surface.
Introduction warm cold roofs this guidance offers guidance on the difference benefits between warm and cold roofs.
A cold roof has the insulation placed below the structural deck which thus remains cold.
During cooler night times and in winter periods the deck temperature can then be below the dew point of the interior air.
Cold roof sheathing is one of many components in keeping ice dams at bay.
Hence the term cold decks construction materials wood based products absorb moisture.
The second and nearly as important goal is to keep the roof deck as cold as possible during upstate new york winter months.
Zones 5 6 7 and 8 in that the manufacturers of these materials assume that roof deck may require ventilation to assist drying.
In cold and very cold climates selecting a roof deck condensing surface temperature criteria of 45 f is very conservative.
The breakdown warm roof vs cold roof.
Polyisocyanurate thermal insulation also referred to as polyiso pir or iso is a popular low slope commercial building roof insulation.